</>EmbeddedInterview

What is SMBus, and what is I3C?

MediumCommunication Protocols

Short answer: SMBus (System Management Bus) is a stricter variant of I2C used for system management (batteries, power supplies, temperature monitors on PC and server boards): it defines voltage levels, a 25–35 ms clock-low timeout, a minimum 10 kHz clock, optional Packet Error Checking (a CRC-8 byte), standard command formats and an alert line. I3C (MIPI Improved Inter-Integrated Circuit) is the modern successor to I2C: push-pull signalling at up to 12.5 MHz (more in HDR modes), dynamic address assignment, in-band interrupts, and backward compatibility with many I2C targets on the same bus.

SMBus details

  • Timeout means a stuck device cannot hold the bus forever (unlike plain I2C).
  • Defined transactions: Quick Command, Send/Receive Byte, Read/Write Byte/Word, Block Read/Write, Process Call.
  • PEC: CRC-8 (polynomial x⁸ + x² + x + 1) over the whole transaction including addresses.
  • SMBALERT#: a shared interrupt line plus the Alert Response Address (0x0C) to find which device raised it.
  • PMBus builds on SMBus for power supply control.
  • Linux: i2c_smbus_read_byte_data() etc.

I3C advantages over I2C

I2C I3C
Speed up to 1 MHz (3.4 MHz HS) 12.5 MHz SDR, ~25–33 Mbps with HDR modes
Signalling open-drain (slow rising edges, power in pull-ups) push-pull for data (open-drain only during arbitration)
Addressing static, set by pins dynamic address assignment, plus 48-bit provisioned IDs
Interrupts separate GPIO per device in-band interrupts on the bus
Power pull-up current lower

I3C is used for new sensors in phones and wearables, and for DDR5 memory module management (SPD hubs).